calculo nivel – [XLS Document]
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 0 0 0 0.887 1
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= 0 mbar 0 mbar 0 mbar
0 mbar 0 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= 0 mbar 0 mbar
H L
0 mbar 0 mbar
SPAN=
0 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 0 141 141 0.887 1
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLXZ
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -138.371 mbar -15.6359 mbar -122.735 mbar
-138.3709519 mbar -15.63591757 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm 3 gr/cm gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -138.371 mbar -15.6359 mbar -122.735 mbar
-138.3709519 mbar -15.63591757 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 0 141 141 0.799 1
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -138.371 mbar -27.8126 mbar -110.558 mbar
-138.3709519 mbar -27.81256133 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= -138.371 mbar
H L
-138.3709519 mbar -27.81256133 mbar
URV= SPAN=
-27.8126 mbar -110.558 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 0 281 281 0.913 1
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -275.761 mbar -23.9912 mbar -251.769 mbar
-275.7605496 mbar -23.99116781 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= -275.761 mbar
H L
-275.7605496 mbar -23.99116781 mbar
URV= SPAN=
-23.9912 mbar -251.769 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 21 311 290 0.674 1
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -284.593 mbar -92.7772 mbar -191.816 mbar
-284.592738 mbar -92.77723258 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= -284.593 mbar
H L
-284.592738 mbar -99.49558391 mbar
URV= SPAN=
-99.4956 mbar -185.097 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 21 311 290 0.674 1
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -284.593 mbar -92.7772 mbar -191.816 mbar
-284.592738 mbar -92.77723258 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= -284.593 mbar
H L
-284.592738 mbar -99.49558391 mbar
URV= SPAN=
-99.4956 mbar -185.097 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 21 311 290 0.674 1
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -284.593 mbar -92.7772 mbar -191.816 mbar
-284.592738 mbar -92.77723258 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= -284.593 mbar
H L
-284.592738 mbar -99.49558391 mbar
URV= SPAN=
-99.4956 mbar -185.097 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 0 982 982 0.86 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -1156.43 mbar -327.655 mbar -828.773 mbar
-1156.42787 mbar -327.6545633 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= -1156.43 mbar
H L
-1156.42787 mbar -327.6545633 mbar
URV= SPAN=
-327.655 mbar -828.773 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 0 982 982 0.86 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -1156.43 mbar -327.655 mbar -828.773 mbar
-1156.42787 mbar -327.6545633 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= -1156.43 mbar
H L
-1156.42787 mbar -327.6545633 mbar
URV= SPAN=
-327.655 mbar -828.773 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 0 982 982 0.86 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -1156.43 mbar -327.655 mbar -828.773 mbar
-1156.42787 mbar -327.6545633 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= -1156.43 mbar
H L
-1156.42787 mbar -327.6545633 mbar
URV= SPAN=
-327.655 mbar -828.773 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 0 119 119 0.796 1
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gs
H L
LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gs+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= URV= SPAN= -116.781 mbar -23.8234 mbar -92.9578 mbar
-116.781158 mbar -23.82335623 mbar
CUANDO LA TOMA DE ALTA SE SELLA CON EL MISMO PRODUCTO
X= Y= Z= Drm gp= gs=
0 0 982 982 0.817 1.2
cm cm cm cm gr/cm3 gr/cm3
HLDrm
gs
gp
LLX Z
Y
gp LRV=4ma=-(z*gs)+(y*gs+x*gp) URV=20ma= -(z*gs)+(y*gp+x*gp+Drm*gp) CALIBRACION DEL INSTRUMENTO LRV= -116.781 mbar
H L
-116.781158 mbar -23.82335623 mbar
URV= SPAN=
-23.8234 mbar -92.9578 mbar
CALCULO DE RANGO PARA TRANSMISORES DE NIVEL MARCA R0SEMOUNT MODELO 3051CD
X= Y= Z= Drm gp= gs=
0 0